Note:
These files open in PDF format, which requires
Adobe Acrobat Reader
.
PPMS
®
Application Notes:
General System
Reading and Creating Calibration Tables for Sensors
(1/06) - 1070-808
Magneto-Resistance Calibration Wizard for Cernox Thermometers on the User Bridge
(2/06) - 1078-202
Magnetic force bending PPMS® Probe causes temperature control problems
(6/01) - AR10
Interfacing Third Party Instruments to the PPMS® Software Environment
(4/02) - 1070-202
Inductive Cross-Talk during Alternating Current Measurements: Guidelines for Sensitive Measurements
(5/99) - 1584-202
Distorted low-level signal readback of AC signals in the PPMS® in the temperature range 25-35 K due to Inconel mitigation of inductive cross talk
(7/00) - AR04
Cause and Effects of Common-Mode Leakthrough
(11/00) - 1584-201
Stray Magnetic Fields and Quantum Design Cryostats
(1/08) - 1070-204
<UPDATE!
Heat Capacity
Non-smooth Specific Heat Between 200 K and 300 K due to Anomalous Specific Heat of Apiezon N-grease
(5/02) - 1085-152
The Heat Capacity of the Addenda is a function of magnetic field below 10 Kelvin
(6/01) - AR01
Scatter in Heat Capacity Data Below 2 K Due to Vibration of Heat Capacity Platform
(6/01) - AR09
Oscillations in the PPMS® Heat Capacity Measurements with Helium-3 in a Magnetic Field
(6/01) - AR03
Helium Cryopumped on Heat Capacity sample causes peak in low temperature Heat capacity
(6/01) - AR02
Anomalously Low Heat Capacity Below 1K
(5/02) - 1085-151
Improved Method for Determining Heat Capacity in Large Magnetic Fields
(1/04) - 1085-154
Saving the Raw Data from Heat Capacity Measurements
(7/04) - 1085-155
ACMS
AC Susceptibility
(12/02) - 1078-201
Calibration Procedure for the PPMS® P500AC Susceptibility and DC Magnetization Option (ACMS)
- (11/00) - 1084-302
Measurement of Electrical Resistivity Without Contact Using the ACMS (page 2, Quantum States Issue 7)
- (2/98) - qs7
The ACMS Image Effect
(11/00) - 1084-305
Using the ACMS Coil Set with an Anti-Static Shield
(06/04) - 1084-202
ACMS DC Analysis Centering Techniques: Linear vs. Nonlinear Mode
(06/06) - 1084-310
AC Transport
Using the Horizontal Rotator Option in Conjunction with the AC Transport Option
(5/99) - 1070-204
AC Transport "constant current" vs. "low impedance" modes (6/07)
- 1084-402
<NEW!
Resistivity
Performing van der Pauw resistivity measurements using the QD PPMS
(3/07) - 1076-304
Using the PPMS® Resistivity Option in Voltage Mode
(9/04) - 1076-303
VSM
Performing VSM Measurements in PPMS® High-Field (14-T or Higher) Magnets
(11/03) - 1096-301
Measuring Temperature-Dependent Magnetization with the PPMS® Vibrating Sample Magnetometer
(11/03) - 1096-302
Mounting Samples Loosely Causes Moment Noise in VSM Measurements
(9/04) - 1096-303
Sample Centering and Temperature-Dependent Magnetization Measurements using the PPMS® VSM
(7/07) - 1096-305
VSM Sample Mounting Techniques (7/07) - 1096-306
<NEW!
EverCool™
Magnet Ramping Guidelines for an EverCool Dewar
(3/05) - 1099-205
Custom Measurements
Hall Probe Magnetometry using the PPMS (2/08)
- 1084-701
<NEW!
WORLD HEADQUARTERS:
6325 Lusk Boulevard
San Diego, CA 92121-3733, USA
1.858.481.4400 Tel
1.858.481.7410 Fax
Info@qdusa.com
COPYRIGHT © 2000, QUANTUM DESIGN, ALL RIGHTS RESERVED.